Product image

Hikvision DS-UPS600 UPS, 600 VA / 360 W, Built-in AVR, 4-6 hours recover to 90% capacity, Surge protection

FromOMR 13.500
Hikvision DS-UPS600 UPS, 600 VA / 360 W, Built-in AVR, 4-6 hours recover to 90% capacity, Surge protection—
OMR 13.500
  • Fast delivery

    Ships in 2–4 business days across Oman.

  • Easy returns

    30-day money-back guarantee, no fuss.

  • Secure checkout

    Encrypted payments you can trust.

Description

table { border-collapse: collapse; width: 100%; } tr { border-bottom: 1px solid rgb(222, 226, 230); } td { padding: 8px; margin: 0; } td:first-child { font-weight: bold; color: #333; } h3 { margin-top: 10px; } 

Hikvision DS-UPS600 UPS, 600 VA / 360 W, Built-in AVR Power

UPS Capacity600 VA / 360 W
Input Voltage Range85 VAC to 150 VAC
Input Frequency50/60 Hz self-adaptive
Plug TypeType B (NEMA 5-15)
Output Voltage Range110 VAC to 125 VAC
Output Frequency50/60 Hz ?? 0.5 Hz self-adaptive
Transfer Time??? 10 ms
WaveformPWM
Outlet TypeType B (NEMA 5-15)
Outlet NumberBattery outlet*4 & Bypass*2

Battery

Battery Type12 V/7 Ah, lead-acid battery
Recharge Time4-6 hours recover to 90% capacity
Typical Backup TimeRun time at 60w: 35 min
Run time at 100w: 20 min
Run time at 200w: 3 min

Interface

Communicate PortsNo

Protection

Full ProtectionSurge protection, Overload protection, Discharge protection, Overcharge protection

Indicator

DisplayLED indicator
Working Mode (AC Mode)Solid green
Charging Mode (DC Mode)Solid red
Overloading ModeFlashing yellow

Alarm

Charging Mode (DC Mode)Sounding every 8 seconds
Low BatterySounding every second
Overloading ModeSounding every 0.5 seconds
FaultContinuously sounding

General

Operating Temperature0 ??C to 40 ??C (32 ??F to 104 ??F)
Operating Humidity30% to 90% (non-condensing)
Dimension274 mm ?? 95 mm ?? 139 mm (10.79" ?? 3.74" ?? 5.47")
WeightApprox. 4.2 kg (9.26 lb)

Specifications

SKUUPS-HIKVISION 600VA
DisplayLED indicator
WaveformPWM
Plug TypeType B (NEMA 5-15)
Low BatterySounding every second
Outlet TypeType B (NEMA 5-15)
Battery Type12 V/7 Ah, lead-acid battery
UPS Capacity600 VA / 360 W
Outlet NumberBattery outlet*4 & Bypass*2
Recharge Time4-6 hours recover to 90% capacity
Transfer Time??? 10 ms
Full ProtectionSurge protection, Overload protection, Discharge protection, Overcharge protection
Input Frequency50/60 Hz self-adaptive
Source Categorycomputer-peripherals/power-protection/ups
Output Frequency50/60 Hz ?? 0.5 Hz self-adaptive
Overloading ModeSounding every 0.5 seconds
Communicate PortsNo
Input Voltage Range85 VAC to 150 VAC
Typical Backup TimeRun time at 60w: 35 min Run time at 100w: 20 min Run time at 200w: 3 min
Output Voltage Range110 VAC to 125 VAC
Working Mode (AC Mode)Solid green
Charging Mode (DC Mode)Sounding every 8 seconds